HDJY-2000 series manual/automatic dosing device (pure water dosing)
Realize 24-hour continuous control throughout the day, with a control accuracy of 0 5% -1% Can save more than 30% of medication usage
Online customer service:
- Product Introduction
- Technical Parameter
introduction
This device consists of a metering pump, a dosing tank, a mixer, a liquid level gauge, a scale inhibitor, a safety valve, a pressure gauge, and an electrical control cabinet (including a frequency converter). This system has the characteristics of reasonable design, high automation, safe and reliable operation, and simple operation. Widely used in water treatment and dosing systems for power plant feedwater, boiler water, raw water, circulating cooling water, and industrial wastewater and sewage. Pure water dosing includes: ①(?) adding ammonia to feedwater and condensate; ②(?) Adding hydrazine to water supply; ③(?) Add phosphate to the furnace. All of the above are for furnace dosing. Raw water and other additives include: ①(?) adding coagulants and coagulant aids to raw water (raw water); ②(?) Circulating water with stabilizer (corrosion inhibitor), scale inhibitor, and mixed bacterial agent; ③(?) The condenser is coated with ferrous sulfate, all of which are added outside the furnace. This series of dosing devices has been applied in dozens of various types of units and other enterprises in China, and has been highly praised by users.
HDJY-2001 is for pure water dosing, and HDJY-2002 is for external wastewater dosing. (Optional)
Characteristics
Realize 24-hour continuous control with a control accuracy of 0.5% -1%.
Can save more than 30% of medication usage.
Automatic monitoring and control, saving manpower.
The monitoring system can achieve networking.
Adopting computer control, the software design is flexible and can achieve various reports to meet the requirements of different users.
Advanced intelligent fuzzy regulation, output standard 4-20mA regulation signal and complete control unit composed of frequency converter.
Equipped with various control methods such as manual, automatic, and soft manual. Maximize the satisfaction of on-site requirements.
For different medicinal liquids, automatic dispensing and stirring can be achieved through a PLC system.
The solution tank, metering pump, system pipeline, and control system of the dosing device are centrally arranged to form a compact small unit structure, which is convenient for the design department's design and daily maintenance of users.
The solution tank, metering pump, and system pipeline prepared by the dosing device are all designed with anti-corrosion measures as needed. The main components in the control system are all products from internationally renowned companies.
The control system is equipped with functions such as electrical protection, low liquid level alarm, and automatic pump stop at low liquid level.
The data adopts Samsung's storage technology from South Korea, greatly increasing the amount of data. It can store tens of thousands of sets of measurement data and 5000 system operation records (known as the 5000 notepad function).
Application: In the fields of chemical engineering, fertilizer, metallurgy, etc. in thermal power plants, as well as in situations where (20~170) L/h boiler water, circulating internal cold water, industrial pure water, wastewater, and sewage are added with chemicals
Model | Ammonia dosingHDJY-2001A | Adding hydrazineHDJY-2001B | Adding phosphateHDJY-2001C |
Container Capacity | (0.5~2)m3 | (0.5~2)m3 | (0.5~2)m3 |
Tank material | stainless steel | stainless steel | stainless steel |
Pump type | Mechanical diaphragm pump | Mechanical diaphragm pump | Hydraulic diaphragm pump |
total power | (1~2.4)MPa | (1~2.4)MPa | (5.0~24)MPa |
total power | (3~6)KW 2 boxes and 3 pumps | ||
Mixer configuration | 380V、(?)960PRM、(?)power(0.37~1.2)KW |
Standard configuration
combination | One box with one pump, one box with two pumps, two boxes with two pumps, two boxes with three pumps, two boxes with multiple pumps, etc. (determined according to the dosing point) -2001A |
Medicine box materials | Carbon steel, stainless steel, fiberglass, and PE fiberglass |
Container Capacity | (1×(?)0.5、(?)2×(?)0.5、(?)1×(?)1.0、(?)2×(?)1.0、(?)2×(?)2.0、(?)1×(?)5.0、(?)1×(?)10.0)m2(quantity ×(?) volume) |
Mixer configuration | 380V、(?)960PRM、(?)power0.37-0.74KW |
Measurement pump configuration | Select a metering pump based on dosage, medium type, and system pressure |
Pump type | Mechanical diaphragm pump |
External dimensions | (1800×(?)850×(?)1900及(Ji)2900×(?)1100×(?)2200)mm (wide ×(?) high ×(?) deep) |
Weight | (2~5)t |
classification | name | Model | Unit set combination form | Tank volume((?)m3)(?) | Technical parameters of the pump | electric load(KW) | load(t) | ||
flow(L/H) | pressure(MPa) | power(KW) | |||||||
Raw water dosing | Flocculant adding device | HDJY-2002A | One box with two pumps or two boxes with two pumps | 1~2 | 50~100 | 0.32~1.0 | 0.55&1.5 | 3~8 | 2.5~5 |
Alkaline adding device | 2 | 15~400 | 0.8~2.0 | 0.75&1.5 | |||||
Adding coagulant aid device | 1~2 | 5~1000 | 0.32~1.0 | 0.55&1.5 | |||||
Circulating water dosing | Circulating water corrosion inhibitor device | HDJY-2002B | Two boxes, two pumps, one box, two pumps, two boxes, three pumps | 1~2 1~3 | 50~70 | 0.37~1.0 | 0.55~1.5 | 3~8 | 2~6 |
Circulating water scale inhibitor device | |||||||||
3.6 | 0.15 | 1.5 | |||||||
Circulating water and sterilization device | |||||||||
Boiler start-up layer dosing | Ammonia dosing device | HDJY-2001A | One box with two pumps | 0.5~1 | 20~50 | 1.6 | 0.37 0.55 | 3 | 2.5 |
Phosphate addition device | Two boxes and three pumps | 4.2~6.3 | 0.55 0.75 | 4 | |||||
Coating of condenser | Condenser coating device | HDJY-2002C | One box, one pump | 1~3 | 2~4 | 0.4 | 3 | 5~6 | 2~5 |
Two boxes and two pumps | 10~11 | 3~7.5 |